Attach a blue hose to the left fitting (your left when facing the screen) and a red hose to the right fitting, using the opposite end of the hose from the hose’s valve or check valve. Make sure the valves on the manifold are closed. The right, red side is for the compressor discharge or high-side of the unit.ĬHECKING THE PRESSURES AND TEMPERATURES OF AN HVAC UNIT On the left (your left when facing the screen), the blue side of the manifold is for the HVAC unit’s compressor suction or low-pressure side. To turn the manifold off, press the power button while the screen is on. To turn the display back on, touch anywhere on the screen or press the power button. Minutes after the screen turns off before turning off completely. The display will turn off (sleep) after four minutes. Note: You might have to keep the button pressed a little longer than you are used to. Use a light touch on the screen to activate a button. That means you can use any non-scratching item to press the buttons on the screen. The manifold has a resistive touch screen. If the unit flashes white but does not turn on, you might need to press the button and hold it a little longer. The screen will flash white, go black, then the unit will start up. To turn the unit on, press the on/off button. If the unit is disrupted by ESD, it could affect the display and the unit may restart.

  • Your digital manifold has been designed to eliminate the damaging effects of Electric Static Discharge ESD.
  • This will result in incorrect temperature probe readings.

    deepvacuum first directory at level

    Do not set manifold on top of an A/C system.The sensors will not give accurate readings if the battery level is in red. If the battery indicator is red, charge the manifold before use.If eyes come in contact with refrigerant, immediately flush with plenty of water.Auto-Off: after 30 minutes, sleep mode 4 minutes.Battery Life: 30-36 hours normal use (25-30 hours with Bluetooth® enabled).Power: Li-Ion rechargeable battery (charge through supplied USB type C cable).Connections: 1/4” m-flare and 3/8” m-fl (vacuum hose connection (4 way only)).Vacuum Sensor: Range 20,000 to 1 micron.Operating Temperature: 32 to 122˚F (0 to 45˚C).Refrigerant Temperature Range: -40 to 200˚F (-40 to 93˚C).Proof Pressure: 1000 psi (70 bar, 7 MPa, 70 kg/cm2)(Tolerable pressure without internal damage).Working Pressure: 0 to 725 psi (50 bar, 5 MPa, 52 kg/cm²).Sensing Accuracy: ☑ psi or 1% of reading (whichever is greater).Deep Vacuum Display: micron, mBar, kPa, Pa, Torr, mTorr, mmHg.Pressure Display: psi, bar, MPa, kg/cm2, kPa.

    #Deepvacuum first directory at level manuals#

    7.2 Related Manuals / Resources SPECIFICATIONS






    Deepvacuum first directory at level